In a study based on cooling data of three hypoeutectic Al-Si alloys, nine interfacial heat transfer models were compared in the same statistical framework. The 3% and 9% Si alloys support the time-exponential model, while the 7% Si alloy retains three approximately constant candidates. Model selection depends not only on curve fitting, but also on prior, measurement error, and parameter sensitivity.

Figure 1: Schematic diagram of vertical unidirectional solidification device, including heater, thermocouple, ingot and bottom cooling system.

Figure 1: Schematic diagram of vertical unidirectional solidification device, including heater, thermocouple, ingot and bottom cooling system.

Nine Candidate Models from Directional-Solidification Temperature Data

The heat transfer between metal and mold is an important boundary condition for temperature field calculation during casting solidification. The interfacial heat transfer coefficient IHTC determines the thermal resistance of this section, and affects the solidification rate, thermal gradient and subsequent microstructure prediction. There are not only constant forms but also expressions varying with time, temperature, interface position or contact heat conduction conditions in literature. Different models may be close to a cooling curve after tuning parameters, but the closeness of the curves does not mean that each model has obtained the same degree of data support.

Stieven et al.'s work moves the question from "how to call up a set of fitting parameters" to "which mathematical form is more plausible given data and assumptions." The author compares 9 existing models, and the number of parameters varies from 1 to 4, and does not propose a new interfacial heat transfer formula. In this paper, SMC ABC is calculated by combining MFO and sequential Monte Carlo approximation. The reasonable initial range of parameters is established first, and then the sampling tolerance is tightened, so that the candidate model and its parameters are tested by the same temperature data.

Three hypoeutectic alloys Al-3wt. % Si, Al-7wt. % Si and Al-9wt. % Si were used. The temperature profiles in this paper are derived from existing directional solidification studies, and the original paper clearly states that no physical tests were re-conducted. The apparatus and techniques reproduced are taken from published work by Peres et al. to illustrate the measurement conditions on which calculations are based. Therefore, the statistical inversion in this paper is a reanalysis of historical measured data, and the device preparation and cooling program is used to define the experimental background of this batch of data.

In the original experiment, the vertical upward unidirectional solidification device was used, and the heat was extracted mainly through the bottom cooling plate. SAE 310 stainless steel plates with a thickness of 4 mm were used for the metal-mold interface, and type K thermocouples were placed 4, 8, and 12 mm from the bottom heat extraction interface to record transient temperatures during solidification. The mold and base plate are pre-ground and coated with an alumina-based suspension, dried and sealed with a material such as ceramic fiber paper to reduce the risk of leakage and improve the consistency of interface preparation. Figure 1 in the original text shows the device and heat extraction direction.

After the alloy is melted and homogenized, it is poured into the mold. The resistance heater of the directional solidification furnace is initially kept on to stabilize the system at the preset pouring temperature Tv. When the first thermocouple reaches the reference temperature, turn off the heater and immediately start the cooling medium to start the upward directional solidification until the ingot is cooled to room temperature. Such a procedure relates the initial temperature, the cooling start time, and the location of the measurement points, providing a clear temporal and spatial boundary for the inversion model, rather than extrapolating the heat transfer process solely from the tissue photos after solidification.

For the forward problem, the finite volume method is used to calculate the temperatures at different positions, following the existing one-dimensional solidification heat transfer model. 1-D approximation is adopted because the heat extraction is mainly along axial direction, the sidewall is insulated, and the radial heat transfer is relatively weak. Natural convection is also neglected under the vertical solidification conditions discussed. This simplification significantly reduces the cost of repeated solutions and facilitates extensive parameter sampling, but it depends on the heat transfer conditions of a particular device and does not mean that multidimensional flow, mold filling, and heat exchange in complex practical castings can be omitted altogether.

the energy equation retain that release of latent heat of solidification and describes the liquid-solid transition in term of the local solid fraction fs. Voller's back diffusion model was used for solid fraction, and the parameters involved solid diffusion coefficient, partition coefficient, second dendrite arm spacing and final solidification time. Formula (6) in the original text writes the time derivative of solid phase rate as the product of temperature derivative and cooling rate, and then constructs the equivalent specific heat cp=cm-L·fs/T from Formula (7), including latent heat contribution into the solution; where L is the latent heat and cm is the specific heat obtained by mixing the solid and liquid in proportion.

Density, thermal conductivity and specific heat vary with temperature and solid-liquid ratio, rather than taking the same constant throughout the solidification process. Convective heat transfer with the environment is used at the upper boundary, and the total heat transfer coefficient U is used at the bottom to represent the cooling chain. The original formula (11) series the bottom thermal resistance as U=1/[1/hwater+ mold/kmold+1/hi], corresponding to cooling water convection, mold bottom plate heat conduction and metal-bottom plate interface thermal resistance respectively; The initial temperature is T(z,0)=Tv according to equation (12). The estimated hi is only a fraction of the total thermal resistance and cannot directly replace the entire U.

The nine candidate models are numbered as in Table 1. Model 1 treats hi as a constant; Model 2 uses the combination of mold and metal thermal conductivity and one undetermined parameter; Model 3 is a power law of time and model 4 is a power law of temperature. Model 5 weighted solid contact heat conduction and interstitial air heat conduction; Model 6 is time exponential decay. Model 7 introduces the distance from solidification interface to boundary, model 8 introduces time offset and three parameters, and model 9 describes the interface change by four-parameter temperature function. Different forms express different boundary response assumptions.

Table 1:9 candidate interface heat transfer models
serial numberExpression for hiNumber of parameters
1P11
2P1·kmold·kmetal/(kmold+kmetal)1
3P1·t^P22
4P1·T^P22
5[kweig·P2+kair·(1-P2)]/P12
6P1·exp(-α·P2·t)2
7P1+P2^(-Zint/P3)3
8P1·P2^P3·(t+P2)^(-P3)3
9P1-P2/{1+exp[(T-P3)/P4]}4

The original formula (18) of model 6 is hi=P1 exp(-αP2t). P1 has units of W·m⁻²·K⁻¹ and P2 has units of m⁻²; α is the thermal diffusivity of the metal and t is time. The author relates this form to the solution of 1-D transient thermal diffusion equation: temperature and thermal gradient may contain the same exponential time term, and the corresponding expression can be obtained under the assumption that the interface heat extraction coefficient is dynamically related to the thermal gradient. So it has physical and mathematical explanation, but still need data to judge its suitability in the specific conditions.

Parametric search is not an arbitrary attempt on all real numbers. Table 2 specifies the search interval for each model, e.g. P1 is 1000 - 10000 for constant models, P1 is 1000 - 15000 for time exponential models, and P2 is 0.001 - 1000. The initial interval for the power law exponent of time is − 0.5 to − 0.00005. The author points out that some intervals are determined after narrowing down the search domain gradually, and not all of them can be directly given by independent physical measurements. This is also why subsequent probability results need to be read along with prior settings.

MFO first takes the root mean square difference between the numerical temperature and the measured temperature as the target to find the better parameter vector of each model. Equation (22) is F(θ)={Σ[Xi-Yi(θ)]²/Nmeas}¹ᐟ², where Xi is the measured value and Yi is the value calculated by the forward problem. The maximum iteration number is set to 200, and the number of searching individuals is 10 times of the number of parameters to be estimated; The stopping criterion is met when parameter changes do not exceed 10⁻¹⁰ over 15 consecutive iterations. The spiral-shape parameter bMFO is set to 1.

The resulting individual values are then taken as the mean of the Gaussian prior, with the standard deviation set at 20% of the magnitude of the optimized values. This step narrows the scope of SMC-ABC exploration without directly recognizing the optimization results as the final answer. Table 3 - 5 lists the optimal parameters and objective function values of the nine models for the three alloys, respectively. Subsequent samples continue to estimate the parameter distribution and test whether the different models can still explain the temperature response under stricter tolerances.

Bayesian inference combines prior information with data constraints to obtain posterior distributions of models and parameters. Because it is difficult to write an explicit likelihood function for this problem, ABC uses whether the distance between simulated data and measured data is less than the tolerance to decide acceptance; The SMC then progressively tightens the tolerance through successive populations. One optimization answer is "find out what parameters fit," and the sampling process further answers "which parameter intervals and model forms are consistently acceptable to the data." The roles of the two in the study are different.

Each generation of SMC ‑ ABC uses 500 particles, which is not the same setting as the number of individuals searched by the MFO. During initialization, the extraction weights of models 5 and 6 are set to 3, and the rest are set to 1, reflecting the prior judgment of the author on the physical correspondence between the two models; This extra weight is applied only to the first generation and is not continuously applied to them in subsequent resamplings. Whether the model ultimately survives depends on acceptance after tightening tolerances, and "draw more initially" should not be confused with "higher probability in the end."

Convergence is based on Morozov's deviation principle, which reconciles the final data variance with the assumed measurement error rather than pursuing the numerical curve fit indefinitely. Due to the lack of repeated test statistics, the author gives an estimation of type B uncertainty with reference to instrument accuracy and calibration information: thermocouple accuracy is 0.1%, and 0.2% of local measured temperature is used as effective standard deviation for calculation to take into account the influence of collection chain and installation. Generation-by-generation tolerance is taken as the first quantile of the particle mismatch distance vector, instead of 0.2% as the per-generation tolerance.

Model Selection, Parameter Ranges and Error Bounds for Three Alloys

The MFO phase has shown that there are differences in the form of different functions. For 3% Si alloy, the objective function of Model 6 is 19.03 K, which is lower than that of Model 1 (25.95 K), Model 2 (28.73 K) and Model 9 (22.95 K). For 9% Si alloy, model 6 is 24.32 K, which is also lower than 27.69 K for constant model and 26.87 K for model 9. The numerical value here is the optimization objective function, not the error of each measuring point after the final sampling, nor the measurement accuracy of the thermometer.

The initial ordering for the 7% Si alloy was different: 29.59 K for Model 6, 28.01 K for Model 9, 31.51 K for the constant model, and 35.05 K for Model 5. Model 9 is slightly better with only one optimization; After entering SMC-ABC, which considers prior, error tolerance and parameter distribution, this combination is not preserved. This shows that the statistical selection mentioned in the study is not equivalent to sorting the 1st order minimum root mean square error of each model and then mechanically selecting the smallest one.

For the 3% silicon alloy, Figure 2 shows that Models 2, 4, and 5 lose accepted particles starting from the second generation; At the third generation, model 6 was dominant, but its parameters did not meet the stopping condition, so it continued to filter until the fourth generation. The posterior probability of the final model 6 is 1, i.e., the remaining forms are not retained under the candidate set, prior, and tolerance conditions of this study. Model 5, which had a higher initial weight, was also eliminated, indicating that initialization did not guarantee its final selection.

Figure 2: SMC-ABC generation model screening for Al-3wt. % Si.
Fig. 2. Selection of the SMC-ABC Generation-by-Generation Model for Al ≠ 3wt.%Si.

Figure 3 compares the distributions of Model 6 parameters in the first and last generation, and Table 6 gives more accurate statistics. P1 had a mean of 9298 W·m⁻²·K⁻¹ and a standard deviation of 99, with 5% and 95% quantiles of 9135 and 9454; P2 had a mean of 101.9 m⁻² and a standard deviation of 3.48, with corresponding quantiles of 96.36 and 107.6. The parameter distributions were significantly narrowed, indicating that under this set of data and model assumptions, the two parameters were strongly constrained.

Figure 3: Initial and final distributions of model 6 parameters in Al-3wt. % Si.
Fig. 3 Initial and final distributions of Model 6 parameters in Al ≠ 3 wt. % Si.
Original Table 6: Al-3wt. % Si, Final Parameter Distribution of Model 6
parameterleast value5% Fractilemean value95% Fractilemaximumstandard deviation
P1 / W·m⁻²·K⁻¹9085913592989454949199
P2 / m⁻²95.4096.36101.9107.6108.43.48

Figure 4 further juxtaposes the temperature curves calculated by the model with the original three thermocouple measurements. This comparison preserves the location of the measuring points, so the reader can see whether the model is only valid close to the cooling floor, or whether it can also reflect the solidification process at further locations. The temperature band in the figure reflects the 95% confidence interval given in the paper and should not be mixed with the 5%-95% parameter quantile interval in Table 6; The former is an expression of uncertainty for curves, while the latter is a distribution statistic for specific parameters.

Figure 4: Measured and calculated temperature curves for Al-3wt. % Si.
Fig. 4. Measured and calculated temperature profiles for Al3 wt. % Si.

The results for the 7% silicon alloy did not converge to a single model. Figure 5 shows that models 4, 6 and 8 are eliminated at generation 2, and models 5 and 9 are eliminated at generation 3; By the fourth generation, models 1, 3 and 7 all satisfy the bias criterion, with posterior probabilities of 0.352, 0.252 and 0.396, respectively. Although their expressions are different, they do not form a clear enough difference between good and bad within the allowable error scale of this set of data. This exception shows that the same selection procedure can yield different retention sets on different component data.

Figure 5: Generation-by-generation model selection of Al-7wt. % Si, with models 1, 3, and 7 retained.
Fig. 5 Generation-by-generation model screening of Al ≠ 7wt.%Si, with models 1, 3, and 7 finally retained.

Table 7 compares the relative support of the three with Bayesian factors. For example, model 1 is 1.4 relative to model 3, model 7 is 1.12 relative to model 1, and model 7 is 1.57 relative to model 3; The inverse comparison takes the corresponding reciprocal. Such differences do not form evidence of a clear bias towards one model or another. The highest posterior probability is 0.396, and the relative support of the three forms is close, so the set of models that meet the condition in common is finally retained.

Further parameter-sensitivity analysis shows that all three retained models approach an approximately constant response, with heat-transfer coefficients of about 4300–4500 W·m⁻²·K⁻¹. In Figure 6 and Table 8 of the original text, the mean value of P1 in Model 1 was 4352, that in Model 3 was 4353, and that in Model 7 was 4419, and the standard deviations were 19.78, 19.74, and 16.48, respectively. P2 of model 3 and P2 and P3 of model 7 showed no significant shrinkage of uncertainty, indicating that the data were insensitive to these parameters.

Figure 6: P1 distribution of three retained models in Al-7wt. % Si.
Fig. 6 P1 distributions of three retained models in Al-7wt. % Si.

Therefore, retaining three models does not necessarily mean obtaining three distinct heat transfer mechanisms. Under this condition and measurement accuracy, different mathematical forms produce almost coincident thermal responses, which are difficult to distinguish from data. Figure 7 only shows the temperature curve of model 1 because the three calculation curves basically overlap when plotted simultaneously, rather than the failure of the other two models. When evaluating the model identification results, we must look at the probability, the actual shape of the function and whether the parameters are really constrained.

Figure 7: Measured versus calculated temperature curves for Al-7wt. % Si, showing the response of Model 1.
Figure 7 Measured versus calculated temperature curves for Al-7wt. % Si, showing the response of Model 1.

For 9% silicon alloy, models 4 and 8 in Figure 8 are excluded in the second generation, and model 6 reaches a posterior probability of 1 in the fourth generation, which is consistent with the selection of 3% silicon alloy. Although Model 5 has a large initial extraction weight, it still loses acceptance probability as the tolerance narrows. Figure 9 and Table 9 show that, for Model 6, P1 has a mean of 4526 W·m⁻²·K⁻¹ and a standard deviation of 52, while P2 has a mean of 138.7 m⁻² and a standard deviation of 5.63; FIG. 10 shows a measured-calculated comparison of the final temperature profile.

Figure 8: Generation-by-generation model screening of Al-9wt. % Si.
Fig. 8 Generation-by-generation model screening for Al-9wt. % Si.
Figure 9: Initial and final distributions of model 6 parameters in Al-9wt. % Si.
Fig. 9 Initial and final distributions of model 6 parameters in Al-9wt. % Si.
Table 9: Al-9wt. % Si, Final Parameter Distribution for Model 6
parameterleast value5% Fractilemean value95% Fractilemaximumstandard deviation
P1 / W·m⁻²·K⁻¹4436445345264625465652
P2 / m⁻²127.8129.7138.7148.0149.75.63
Figure 10: Measured and calculated temperature curves for Al-9wt. % Si.
Fig. 10. Measured and calculated temperature profiles for Al9 wt. % Si.

P1 decreases from 9298 to 4526, while P2 increases from 101.9 to 138.7, indicating that the coefficient combinations corresponding to the two alloys are not the same. P1 controls the initial amplitude of the model, and the exponential term also contains both the thermal diffusivity α and P2, so it is not possible to claim the complete cooling rate or solidification time by comparing only one parameter. The first proof here is the statistical identification results of the model form and parameters, not the direct measurement of the real interface heat transfer coefficient at each time.

Generation-by-generation tolerance variations are documented in Table 10. For the 3% Si alloy, the value decreased from 88.593 K in generation 2 to 49.003 K in generation 3 and 33.399 K in generation 4; 76.262 K, 60.094 K, 53.676 K for 7% Si alloy; and 74.842, 60.094, 51.408 K for 9% Si alloy. These quantities are mismatch thresholds for the whole sampling acceptance process, and the average difference of individual thermocouple curves is not the same indicator, and one of them cannot be directly regarded as the final temperature error of the model.

Table 11 lists the mean standard deviation between the experimental curve and the numerical curve at each measuring point separately. At 4 mm from the bottom, the temperatures of the three alloys are 5.31 K, 7.18 K and 8.62 K respectively. 6.53, 4.03, 4.71 K at 8 mm; 18.06, 11.41, 10.15 K at 12 mm. The three retention models for the 7% Si alloy have the same results in this table because the responses are very close. These location-dependent data are more indicative of the specific scope of the validation than a statement that "simulation agrees well with test."

Table 11: Mean Standard Deviation of Measured and Calculated Curves
Distance from bottom/ mmAl–3wt.%Si / KAl–7wt.%Si / KAl–9wt.%Si / K
45.317.188.62
86.534.034.71
1218.0611.4110.15

Using the same 0.2% standard deviation for 3 combinations of gold is an important boundary in interpreting results. The author thinks that the difference between 7% Si alloy and the other two groups may be related to the difference of original measurement error. However, the existing literature does not provide sufficient repeat test statistics to estimate the error distribution independently for each alloy. Therefore, whether the 7% data have different uncertainties still needs to be supplemented with experimental statistical tests; This study will be used as a possible explanation for the difference in selection.

Therefore, Table 12 retains two types of conclusions: 3% and 9% Si alloys support model 6 in the proposed framework, 7% Si alloys support models 1,3, and 7, and the three tend to approximate constants. The time-exponential model has a physical explanation for thermal gradient evolution and is also clearly supported in 2-pack gold, but this study does not prove that it is uniquely correct for all aluminum-silicon alloys, all molds, or arbitrary heat extraction conditions. The retention of exceptions aligns model recommendations with the strength of evidence from actual data.

Table 12: Final Model Selection
alloyretention modelposterior probability
Al–3wt.%Si61
Al–7wt.%Si1 / 3 / 70.352 / 0.252 / 0.396
Al–9wt.%Si61

For casting thermal analysis, the value of this work lies in putting the model form, parameter estimation and uncertainty into the same process: first, the positive problem is established according to the real plant, then the candidate function and search range are given, and then the filter is gradually selected under the error scale with evidence. It avoids claiming that the model is valid only by the coincidence of the first order curves, and also reveals that only one group of approximately equivalent models can be obtained when the data are insufficient. It is a direct way to improve the reliability of type selection by adding repeated tests and perfecting the measurement uncertainty of different alloys.

This method is aimed at 1-D directional solidification with bottom heat extraction and three specified aluminum silicon alloys, and does not directly give the process parameters of stainless steel precision castings. When migrating to other materials and equipment, it is necessary to reconfirm thermal properties, interface materials, coatings, measurement points, initial and boundary conditions, and re-estimate parameters and errors. It can be borrowed from the evidence-based heat transfer model selection process: it is clear which forms are supported, and it is clear that parts of the data are temporarily indistinguishable.

Gianfranco de M. Stieven、Daniele S. Stieven、Diego C. Estumano、Edilma P. Oliveira、Erb F. Lins; Iranian Journal of Science and Technology, Transactions of Mechanical Engineering,50,671–689; DOI:10.1007/s40997-026-00961-y。 This paper compiled according to the original paper, maps and data using CC BY 4.0 authorization.Original Paper · PDF · CC BY 4.0 ·