A spherical furan-sand core is immersed in 1315 °C iron while temperature and evacuated gas are logged. More than 80% leaves within 65 s; decomposition, moisture and gas expansion overlap.

Figure 1 . Thermal analysis and gas generation (TAGG) apparatus.

Figure 1 . Thermal analysis and gas generation (TAGG) apparatus.

Spherical Samples, Thermal Boundaries and Gas Measurement

Moisture, binder and intergranular gas heat together when metal contacts a sand mold. Poor evacuation can damage casting quality, while mold absorption changes metal cooling. Uncontrolled heating or condensation makes conventional gas tests hard to relate to pouring. TAGG combines gas evolution measurement and internal-temperature analysis, connecting gas output with heat absorption stages.

A 40 mm spherical core approximates one-dimensional radial transfer in spherical coordinates. Room-temperature samples enter cast iron held at 1315 °C, center 90 mm below the surface, for about 300 s. Direct immersion creates a pouring-like shock rather than slow furnace heating. Spherical geometry helps analysis but does not represent every real core thickness, vent path or contact condition.

N-type TC1 sits at the center and TC2 10 mm radially outward. TC1’s quartz tube, outer/inner diameters 9/7 mm, also vents gas. TC2’s 5/3 mm tube is sealed with refractory powder so gas exits only centrally. A fixture holds the assembly, limiting unmeasured bypass leakage.

Figure 2 . Spherical sample and center/lateral thermocouples.
Figure 2 . Spherical sample and center/lateral thermocouples.

The center connects to a 7/5 mm horizontal quartz tube and resistance-heated line held at 170 °C to limit condensation. Gas displaces rapeseed oil preheated near 140 °C onto a balance. Density 0.85 g/cm³ converts displaced mass to volume. Temperature and mass are recorded five times per second, yielding cumulative volume and gas-rate curves.

The measurement gives evacuated volume under these controlled conditions, not individual chemical concentrations. No elemental gas analysis or separation of combustion from pyrolysis was performed. Total gas/thermal history therefore cannot be read as a hazardous-species concentration or workplace-air assessment.

Three samples use one batch of subangular quartz lake sand, mean grain 0.26 mm, 1.2 wt.% furfuryl-alcohol resin and sulfonic-acid catalyst at 40% of binder mass, not total sand mass. Samples are hand rammed and cured 24 h. A/B/C weigh 53.4/53.5/53.3 g; volume is about 33.5 cm³ and apparent density about 1.59 g/cm³.

Table 1. Sample mass, volume, density and gas output

Sample

Mass (g)

Volume (cm3)

Apparent density (g/cm3)

Gas volume (cm3)

A

53.4

33.5

1.59

1060

B

53.5

1.59

1115

C

53.3

1.59

1129

Similar mass/density gives similar heating. Cumulative evacuation agrees well for 40 s, then A falls behind, ending at 1060 cm³ versus B 1115 and C 1129. No bypass bubbles entering metal were observed. Hand ramming can still vary local radial density, pore space, permeability and oxygen availability despite matching average density, affecting later evolution.

Figure 3 . Temperature and cumulative gas from samples A/B/C.
Figure 3 . Temperature and cumulative gas from samples A/B/C.

Local density/oxygen differences are proposed explanations, not pointwise oxygen measurements. They may change combustion/pyrolysis balance, but reaction fractions were not independently quantified. Thus comparable main heating/early release coexists with later-volume differences, an important boundary when uniform test cores represent real molds.

Fourier Thermal Analysis and Early Gas Sources

FTA extends solidification-latent-heat analysis to heated sand. Original Eq. (1) is ρcₚ∂T/∂t = ∇(k∇T)−q̇_abs: density, heat capacity, conductivity and time-dependent volumetric absorption. A hypothetical conduction-only heating rate becomes a baseline; its difference from measured heating estimates decomposition-related absorption.

Eq. (2) is q_abs = cᵥα∇²T−cᵥṪ. Volumetric capacity cᵥ and diffusivity α combine with spatial temperature differences from TC1/TC2. Eq. (3) defines Z_F = α∇²T, the no-decomposition heating rate. Area between this zero line and measured rate, with iterative property analysis, estimates time-dependent/cumulative absorption; subtracting sand temperature from melt temperature alone does not give decomposition heat.

Thermal interpretation applies to the internal domain bounded by TC2. Unmeasured surface temperature and sequential outer/inner heating prevent matching all gas to one instantaneous TC temperature. The analyzed interval is 88–735 °C, with endpoint volumetric capacities from literature, giving about 650 kJ/kg total absorption. This includes the overall gas-generation interval, not solely resin decomposition; moisture and other processes also contribute.

Figure 4 . Zero line, heating rate and cumulative absorption.
Figure 4 . Zero line, heating rate and cumulative absorption.

More than 80% of total gas leaves during the first 65 s. Figure 5 aligns cumulative/rate curves with inner/outer stages. Immediate outward-layer-to-center transport may reflect intergranular expansion and moisture vaporization. Without interface temperature, the transition to binder decomposition cannot be identified exactly; the first peak is not entirely resin gas.

Figure 5 . Gas rate/volume and inner/outer reaction intervals.
Figure 5 . Gas rate/volume and inner/outer reaction intervals.

At assumed 40% porosity, initial void/air volume is about 13.4 cm³; heating to 88 °C gives about 16 cm³, far below the example’s 1126 cm³. Initial-air expansion alone cannot explain total gas; moisture/binder processes matter. The curve example is 1126 cm³ while Table 1 lists C at 1129 cm³, so they should not be forced into identical precision.

Outer-domain evolution ends near 65 s when TC2 reaches 735 °C. Inner evolution starts near 23 s as TC2 reaches 88 °C, ending near 114 s when center TC1 reaches 735 °C. Overlap during 23–65 s makes total evolution spatially composite. Center temperature alone misses active outer decomposition; outer temperature alone misses later inner decomposition.

After about 114 s, measured heating and zero line converge, indicating decomposition supply is largely finished, yet gas still exits. The final 72 cm³ of the 1126 cm³ example is attributed to subsequent intergranular-gas expansion, not new decomposition. An increasing cumulative curve therefore does not prove continuing resin reaction; thermal state and transport must be considered.

Simultaneous temperature/gas measurement supplies rates, totals and absorption stages under thermal shock, supporting gas-generation/transport/solidification models. Total volume is considered reliable, but temperature-resolved decomposition is approximate because interface temperature is absent and sources overlap. It provides more than one endpoint volume, not complete chemical-mechanism identification.

Displaced oil mass divided by density yields gas volume. Stable oil temperature therefore controls conversion and flow resistance, not merely convenience. Heated lines limit condensation, while preheated oil stabilizes displacement. A constant melt alone is insufficient: cooling lines can condense vapor before measurement and under-represent evacuated gas.

Five synchronized readings per second align temperature and mass. Volume increments give time-dependent evacuation rate and distinguish early peaks from tails. Short fluctuations still require consideration of measurement/transport: gas crosses pores, enters the central tube and travels to the vessel rather than appearing instantaneously everywhere.

Spatial boundaries also matter. Center/lateral temperatures describe the interior, while the earliest-heated surface is unmeasured. Internal reconstruction cannot replace the full surface reaction history. This explains reliable total-gas measurement alongside approximate temperature/mechanism subdivision; their uncertainties must not be interchanged.

Comparisons can vary aggregate/binder/content under common heating, venting and measurement, considering local compaction and permeability. This furan mixture shows strongly early evacuation and about 650 kJ/kg overall absorption. Values are not universal core constants or direct predictions of pores in complex castings; geometry, vent paths and metal solidification must correspond.

Source: Sundaram, Dinesh, Svidró, József Tamás, Diószegi, Attila. Thermal Analysis and Gas Generation Measurement of Foundry Sand Mixtures. 2024-08-02. DOI: 10.1007/s40962-024-01417-2. Adapted from the open-access paper; original figure/table numbers retained. CC BY 4.0.Original paper · Direct PDF · CC BY 4.0 ·