Beyond Scrap Rate: Acoustic Resonance, Mass Compensation and Casting-Lot Traceability


Published: 

2024-06-07

Mass and resonance data from 18 production date codes reveal variation hidden by broad acceptance windows. Investigation of an anomalous lot identifies mixed dates and repeated blast cleaning.

Figure 1 . Automated ART, weighing and sorting system.

Figure 1 . Automated ART, weighing and sorting system.

How Acoustic Testing Produces Comparable Process Data

Scrap rate alone does not establish casting-process stability. A wide acceptance window can reject obvious anomalies while concealing changes among accepted lots. This study records mass and resonance peaks during acoustic resonance testing (ART), extending individual sorting into lot-level process assessment. It concerns production iron castings and repeatability for the same component under consistent test conditions, rather than a universal frequency limit for every material.

One impact excites responses determined by mass, geometry and material properties. The impulse excitation method (IEM) uses an impactor, non-contact microphone, acquisition/FFT analyzer, scale and sorting conveyor. Selected peaks must be distinguishable from noise. The software stores peak limits, actual frequencies and decisions alongside part numbers, dates/lots, mass and overall results, enabling later analysis to trace particular production batches.

ART measures whole-part structural response. Cracks, cold laps, shrinkage, short pours, gross porosity, residual-stress or nodularity changes may alter spectra if they affect structural integrity. Cosmetic flaws still require visual inspection; detecting a difference does not locate or uniquely classify it. A hairline crack detectable in a 226 g part may not be detectable in a 2253 g part. Sensitivity depends on defect size relative to component size and mass.

Supports should minimize contact and damping so the part vibrates freely. Excess restraint reduces amplitude and can shift response. Temperature affects natural frequencies, so lots require stable, comparable temperatures or validated compensation. Excessive impact can produce modulation/nonlinearity. Several positions on one part are tested first; a location giving repeatable isolated peaks of sufficient amplitude is selected and documented in work instructions.

Figure 2 . Typical 0–10 kHz spectrum and selected peaks.
Figure 2 . Typical 0–10 kHz spectrum and selected peaks.

One example uses 320 ms acquisition and 3.125 Hz resolution. Block size and frequency range link these settings; finer resolution usually needs longer recording. The 320 ms is not total cycle time, which includes positioning, weighing, computation, marking and sorting. A typical automated system takes 2.5–3 s per part. The scale should pass gage R&R with total GRR no greater than 10%, otherwise mass compensation can introduce unreliable variation.

Figure 5 . Example settings: 320 ms acquisition, 3.125 Hz resolution.
Figure 5 . Example settings: 320 ms acquisition, 3.125 Hz resolution.

Acceptance criteria should use known acceptable parts and naturally occurring production rejects. Artificial defects may respond differently. Without known rejects, samples must still represent the manufacturing variation. The paper generally recommends 300–500 pieces from one date/lot for high-volume applications, covering every cavity. Multiple later batches must validate stability; a few similar specimens cannot define a permanent window.

Mass variation is important in multi-cavity molds. Lower/inner cavities tend to yield heavier castings than upper/outer ones; variation can reach 20%. Figures 6 and 7 relate cavity location to mass. Uncompensated mass-induced frequency spread can force a wider window and overlap good/bad responses. Usually 3–5 peaks are selected, but the appropriate count depends on the part and detection target.

Figure 6 . Multi-cavity sand-mold layout.
Figure 6 . Multi-cavity sand-mold layout.
Figure 7 . Part mass versus cavity location.
Figure 7 . Part mass versus cavity location.

One uncompensated band runs from just below 2020 Hz to just below 2070 Hz, about 50 Hz wide. Figure 8 shows spectra from 210 castings: a broad window detects only extreme rejects while hiding others in process variation. The system weighs each part and shifts acceptance boundaries along the mass/frequency relation rather than discarding all light/heavy pieces. The parallelogram in Fig. 9 represents the mass-dependent permitted region.

Figure 8 . Responses of 210 castings near the selected peak.
Figure 8 . Responses of 210 castings near the selected peak.
Figure 9 . Mass-dependent frequency acceptance compensation.
Figure 9 . Mass-dependent frequency acceptance compensation.

Compensation reduces frequency width from about 50 to 30 Hz, exposing anomalies previously obscured by overlap. Gage R&R checks peak repeatability/reproducibility before multi-lot use. Compensation does not relax limits or declare every frequency change a mass effect. Repeatedly widening a criterion to reduce scrap can pass bad parts; new process changes require investigation.

Anomalous Lots and Their Cause across 18 Date Codes

Customer drawings specify ±3% for target mass and natural frequency. The foundry adds ±2% control regions and a ±1% goal. Original plots show blue specification limits, red control limits and green goal regions. These serve different purposes: contractual requirements versus early process drift. They are this case’s settings, not replacements for another component’s drawings or statistically derived limits.

The database covers 18 date codes with distributions and statistics including stability index, mean, count, Ppk and Cpk. A stability index near 1 indicates stability; high values flag problems, while insufficient data also affects interpretation. Ppk compares overall spread to specification width; Cpk assesses potential capability. Parts without a date code are marked UNK and excluded from lot statistics despite being inspected, avoiding contamination of between-lot comparison.

Figure 10 . Weight distribution by date code.
Figure 10 . Weight distribution by date code.
Figure 11 . Lot statistics for mass.
Figure 11 . Lot statistics for mass.

Several lots show low mass, sometimes below specification, but with a repeated pattern. Pattern maintenance is one possible front-end issue. Repeatability does not itself mean conformity; it distinguishes persistent offset from a sudden new disturbance. Mean, spread and specification position together separate a consistent low process from one whose average is acceptable but highly variable.

Frequency reveals another pattern. Codes 11 and 13 have broad spreads, but code 11 shifts lower in both mass and frequency, following the observed relation. Code 13 does not, suggesting a structural-response factor beyond mass. Scrap count alone, or treating every shift as mass, misses this. The whole code-13 lot is quarantined and material flow investigated.

Figure 12 . Frequency distribution by date code.
Figure 12 . Frequency distribution by date code.
Figure 13 . Lot statistics for frequency.
Figure 13 . Lot statistics for frequency.

Code 13 includes 3778 pieces, 3475 acceptable. Reject categories are cold laps 27, shrinkage 11, short pours 4 and overblast 261; nodularity, carbides and porosity are zero. Most of 303 rejects are overblast-related. These categories guide investigation; they do not imply one acoustic signal alone located/classified every defect. The explanation combines classification, quarantine and follow-up examination.

Date-code 13 results (table in original Results)
TotalAcceptableNodularityCarbidesCold lapsShrinkageShort pourOverblastPorosity
3778347500271142610

Containers contained mixed date codes, including parts returned for additional blast cleaning. Blasting alters residual stress, shifting frequency peaks and explaining code 13’s broad spread. This is not ordinary cavity mass variation and cannot be corrected simply by increasing casting mass. Without individual records and date traceability, mixed lots and repeated processing might remain an unexplained “unstable date.”

The authors propose linking final inspection with design, tooling, molding, inoculation, pouring, cooling and shakeout, recording events, signal changes and improvement after adjustment. Stable processes still need trend monitoring toward limits. ART thus offers structural-consistency evidence beyond sorting, provided mass, temperature, supports, noise and traceability are controlled together.

Instrument bandwidth must match the part. Some conventional ART systems reach about 50 kHz; newer ones demonstrate 150 kHz on certain components. Most ductile iron responses recur below 10 kHz and gray iron below 5 kHz. Impulse-energy distribution and other modes can reduce high-frequency S/N. Selected peaks must lie within range, with compressed-air/grinding noise isolated; a displayed spectrum does not prove complete coverage.

Impact and microphone time records also require inspection. The impact channel should show one contact; response should decay cleanly without multiple hits or modulation. Peak splitting may follow impact position/asymmetry rather than a new defect. Fixing position, force and supports before comparing repeatable peaks separates measurement changes from product changes and makes statistics useful for root-cause work.

The study demonstrates anomaly detection and cause investigation. A fuller correlation of upstream events with inspection and documented targeted process changes remains future work. It shows how inspection databases reveal variations hidden by scrap rate, not that any single acoustic index directly controls every casting parameter. Drawing requirements and other necessary tests remain; pass rate alone is not proof of stability.

Source: Ward, Rebecca R., Monroe, Charles. Assessing Process Control in the Foundry. 2024-06-07. DOI: 10.1007/s40962-024-01375-9. Adapted from the open-access paper; original figure/table numbers retained. CC BY 4.0.Original paper · Direct PDF · CC BY 4.0 ·