Predicting Ductile-Iron Tensile Strength from Cooling Curves
Published:
2024-01-08
The study used ten years of thermal analysis records and 110 tensile specimens, combined with thermal modulus to establish a multiple regression model, and tested the prediction results with three geometric specimens.
Figure 1 . Cooling curves, cooling rates and characteristic points.
Thermal Analysis Data and Test Methods
The chemical composition of ductile iron can be obtained through spectral analysis, but the actual processes of graphite formation, eutectic solidification and eutectoid transformation need to be combined with thermal analysis to determine. The study used the cooling curves of the Casting Institute of RWTH Aachen University in Germany over the past ten years, correlated them with the mechanical properties of the corresponding castings, and examined whether the tensile strength of castings with different wall thicknesses could be predicted from the temperature-time records of a standard thermometer cup. The research objects include YII, YIV test blocks and cylindrical specimens prepared according to DIN EN 1563. The data used for tensile strength regression involves a total of 110 tensile specimens, and is not an empirical judgment based solely on the temperature curve of a certain heat.
The analysis tool uses a spreadsheet program to automatically import temperature and time series and calculate the first derivative of the cooling curve, which is the cooling rate dT/dt. When the phase change releases latent heat, the cooling rate will change significantly; by comparing the derivative curve with the original temperature curve, characteristic points such as the liquidus line, the start and end of eutectic solidification, the minimum and maximum temperatures of the eutectic, and the eutectoid transition can be identified. Figure 1 shows the temperature curve, cooling rate and identified characteristic points. Each point records not only the temperature, but also the time to reach that point from the beginning of the measurement, so the same set of original curves can derive three types of information: temperature, time and rate.
The study further calculated the temperature difference ΔT, the time difference Δt and the interval cooling rate between the characteristic points, while recording the re-glow and supercooling conditions. The temperature difference reflects the phase change interval, the time difference reflects the cooling time experienced by this interval, and the cooling rate combines the two. The authors pay special attention to these parameters because they influence the formation of graphite nodules, the ratio of pearlite to ferrite in the matrix, and thus the tensile strength. The existing mechanical test results of each heat are manually associated with the corresponding thermal analysis records to avoid mixing the results of different test blocks or different heats under the same cooling curve.
Data analysis first uses univariate linear regression to examine the relationship between each characteristic value and the tensile strength of specimens with different geometries one by one, and compare the explanatory capabilities with the coefficient of determination R². The author used 0.2 as the screening reference value in this study, which does not mean that R² exceeding 0.2 can alone be used as a basis for product acceptance. Considering the different data volumes of the three geometries, the study also set a cross-geometry screening rule: if the R² of a certain variable for the cylindrical specimen is greater than 0.2, a correlation close to 0.2 should also be observed in the YII and YIV test blocks. The final model is based on this combination of multiple variables rather than just selecting a single temperature for extrapolation.
In order to test the model, two sets of identical casting molds were produced, each containing three geometries: YⅡ, YⅣ and cylinder. One set is used to obtain mechanical test samples, and the other set is equipped with thermocouples to record the temperature history of the same sampling position. Figure 2 shows the gating system, and Figure 3 shows the thermocouple and sampling locations. The raw materials are melted and heated to 1500°C, then transferred to the preheated ladle, and covered scrap steel, magnesium and inoculant are added to the ladle. Before pouring the test block, take a small amount of molten iron and pour it into the empty QuiK-Cup thermometer cup and the thermometer cup containing tellurium and sulfur, and use the built-in thermocouple to record the cooling curve. The characteristic values of the stable system solidification thermometer cup are used for prediction, and then compared with the actual measurement results of the test block.


Migrating information from standard thermometer cups to different wall thicknesses is the core difficulty in model establishment. The study included the casting thermal modulus M into the regression, where M is defined as the ratio of volume to surface area. Under the same material and boundary conditions, the thermal modulus is related to the heat dissipation conditions and can be used to relate the cooling process of different geometries. Based on this, the model connects the characteristic values of the temperature measuring cup with YII, YIV and cylindrical specimens to calculate the tensile strength of each geometry. Thermal modulus here is the relationship between geometry and thermal history. It cannot be directly equated to material strength, nor can it eliminate the need for actual measurement verification on different geometries.
Regression results, organizational interpretation and validation
The liquidus temperature T_liq and the time to reach the liquidus line t_liq have low ability to explain the tensile strength in this batch of data; the temperature and time at the beginning and end of eutectic solidification also do not show a stable and strong correlation. In the YII and YIV test blocks, the correlation between some temperature parameters in the eutectic region is obvious, and R² is at a level of about 0.5. When the eutectoid temperature T_ETo increases, the tensile strengths of the three geometries all show an upward trend. Figure 4 shows the relationship between the tensile strength of the cylindrical specimen, the eutectoid temperature, and the time to reach the eutectoid transition, indicating that the second half of the cooling curve also contains important performance information.

The time to reach the eutectoid transition t_ETo is negatively correlated with the tensile strength of the cylindrical specimen, but the performance of this single time variable on other geometries does not satisfy the cross-geometry screening rules, so it is not used as an independent characteristic time point in the final model. Here it is necessary to distinguish between "the total time to reach a certain phase change point" and "the time difference between two characteristic points": the former does not meet the filtering conditions, which does not mean that the latter is also valuable. The study did not simply compress the entire cooling process into the total solidification time, but continued to compare the temperature difference and cooling rate in each phase transition interval.
Temperature differences, re-glow and supercooling within the eutectic solidification interval do not show obvious intensity dependence in these data. What is more explanatory is the temperature difference between the end of eutectic solidification and the eutectoid transition: for the cylindrical sample, the corresponding R² reaches 0.62; for the other temperature difference from the eutectic temperature to the eutectoid temperature, R² is 0.50. However, the correlation of the latter variable in the YII and YIV test blocks was very low, and it failed the cross-geometry screening. The R² of the former variable in the two test blocks were 0.22 and 0.20 respectively, so it was entered into the final model. The trend shown in Figure 5 is that the greater the temperature difference, the lower the tensile strength. Variables cannot be selected based solely on the highest R² of the cylindrical specimen.

Time difference analysis further distinguished the different solidification stages. Table 6 of the original paper shows that none of the time intervals between the liquidus line and the end of eutectic solidification reaches a level of R² greater than 0.2 in these data; the time interval between the eutectic stage and the eutectoid transition is more explanatory. For the cylindrical sample, the two time differences from the end of eutectic solidification to the eutectoid transition, and from the eutectic characteristic temperature to the eutectoid transition, R² are 0.44 and 0.54 respectively. The R² of these two items in the three geometries all exceed 0.2. Figure 6 shows some representative regression results. The longer the interval, the lower the overall tensile strength, which is consistent with the trend that slower cooling corresponds to lower strength.

The time difference in the entire interval from liquidus to eutectoid transition gives R² of 0.18, 0.20, and 0.47 for YII, YIV, and cylindrical samples respectively. This shows that "time parameters are useful" does not mean that every time definition is equally valid, and it also shows that there are differences in the response degrees of different geometries to the same feature. The study compares this time information with temperature and velocity, and then connects the geometry through the thermal modulus, instead of just inferring a seemingly relevant parameter from the final result. When actually establishing a data set, the feature point identification rules, sampling locations, and correlation methods of mechanical results should be consistent in order to reproduce the analysis process used in the paper.
The positive correlation between eutectic temperature and tensile strength also needs to be interpreted with caution. The authors pointed out that the increase in eutectic temperature may be related to longer solidification times or may be caused by alloying elements that affect the eutectic temperature. If it is mainly caused by slowed cooling, it will often be accompanied by the growth of graphite spheres and the reduction of spheroidization rate, which should lead to a decrease in strength; this is different from the direction of the eutectic temperature term in this model. Therefore, the author believes that the observed temperature-intensity relationship is more likely to also include the influence of chemical composition, and the "eutectic temperature increase" cannot be directly regarded as an enhanced control method that can be operated independently.
The lowest and highest eutectic temperatures and the eutectic characteristic temperatures are very close in this batch of records, and their correlation with performance may come in part from this proximity, rather than entirely from three independent mechanisms. Comparison of the original paper found that the eutectic characteristic temperature corresponding to each mechanical index usually has a higher R². Supercooling did not show obvious effects, which may also be related to the better incubation of the test molten iron and the smaller difference between the lowest eutectic temperature and the eutectic characteristic temperature. Therefore, the fact that the influence of a certain parameter does not appear in this data set does not mean that this parameter is not important for all ductile irons; It begins by stating that there are limited changes that can be discerned within the current range of materials and operating conditions.
The cooling rate results are close to the trend reflected by the interval time difference. The cooling rates from the end of eutectic solidification to the eutectoid transition, from the eutectic temperature to the eutectoid transition, and from the liquidus to the eutectoid transition all show certain explanatory capabilities. Figure 7 shows the corresponding regression diagram of the YIV test block. All three intervals show an increasing trend in cooling rate and tensile strength. Table 8 of the original paper lists the temperature, temperature difference, time difference and cooling rate variables used for model development. Different variables need to be screened based on their geometric performance, and parameters with good correlation on a single test block cannot be directly extended to all wall thicknesses.

As the thermal modulus increases, there is an overall decrease in tensile strength, consistent with slower heat dissipation and longer cooling times. However, the R² of the single variable of thermal modulus is only 0.13, which is lower than the reference value of 0.2 used in the study. The author still retains it because the model needs to connect different geometries through this variable. Figure 8 shows the relationship between thermal modulus and strength; this result also shows that the role of thermal modulus cannot be explained independently from chemical composition and structural changes. It has an effect on cooling conditions but is not sufficient alone to give a reliable prediction of tensile strength.

The coefficient of determination of the multiple regression model is 0.77. Table 9 of the original paper gives the coefficients of each variable, and the model intercept is −14612.5. The signs of different temperature and cooling rate terms reflect the statistical relationship in the joint regression, and a certain coefficient cannot be interpreted as an independent physical gain independent of other variables. The intensity expression of the model retains the original formula (4): UTS = 11.38T_TS1 − 19.24T_TS2 + 13.8T_TS3 + 6.2T_TS4 − 0.07ΔT_TS1 − Δt_TS1 + 3.94Δt_TS2 − 749.22(dT/dt)_TS1 + 2467.98(dT/dt)_TS2 + 267.98(dT/dt)_TS3 − 21.09M_TS − 14612.5. The correspondence between each symbol is shown in Table 9 of the original paper; the coefficient of the third cooling rate term in the table is listed as 267.50, which is different from 267.98 in equation (4), and the original values are retained here. The units and variable definitions of the original model must be maintained when using it.
In the verification test, all three geometries showed a trend of increasing wall thickness and decreasing tensile strength, and the predicted directions were consistent with the actual measurements. Table 10 retains the model results, measured values and deviations reported in the original paper: the YII test block is 455.43 MPa and 424.00 MPa, with a deviation of 6.90%; the YIV test block is 438.98 MPa and 402.50 MPa, with a deviation of 8.31%; the cylindrical sample is 406.29 MPa and 396.88 MPa, with a deviation of 2.32%. The authors report an average bias of 5.84%. The model predictions for the three geometries are all higher than the actual measurement results, so we should not just look at the average deviation, but also pay attention to the consistent overestimation phenomenon in this direction.
The explanation at the organizational level focuses on the two stages of eutectic and eutectoid. When cooling is faster in the eutectic stage, the graphite balls are finer and more evenly distributed, and the primary austenite structure is also finer; these structural characteristics will affect the subsequent formation of ferrite or pearlite. The higher cooling rate in the eutectoid stage is conducive to higher pearlite content and finer pearlite structure, increasing the interface that hinders dislocation movement, thereby improving strength. Conversely, slower cooling may form coarser graphite nodules and more ferrite, corresponding to lower hardness and tensile strength. The rate information in different intervals in thermal analysis is therefore more worthy of combined tissue interpretation than pure liquidus temperature.
The model still has clear boundaries of applicability. First of all, the author assumes that the temperature measuring cup can correspond to the characteristic temperature of each geometry, but in reality it is not exactly the same under different wall thicknesses. Secondly, geometries are related through thermal modulus, and thermal modulus itself has limited ability to explain strength in a single variable; chemical composition may also offset the effect of cooling rate on tissue to a certain extent. Finally, the mechanical properties of ductile iron are determined by multiple interacting factors, and continuing to add and standardize the data will help improve the model. The study demonstrates the feasibility of migrating standard thermometer cup information to different geometric performance predictions, while retaining the necessary place of casting verification and structural interpretation in the use of the model.
characteristic temperature | temperature difference | time difference | cooling rate | |
|---|---|---|---|---|
T_eut, min T_eut | T_eut, max T_ETo | Δ T_eut, end-T_ETo | Δ t_eut, end-t_ETo Δ t_eut-t_ETo | dT/dteut, end−ETo dT/dteut−ETo dT/dtliq−ETo |
variable | coefficient | symbol |
|---|---|---|
T_eut, min | 11.38 | T_TS1 |
T_eut | − 19.24 | T_TS2 |
T_eut, max | 13.80 | T_TS3 |
T_Eto | 6.20 | T_TS4 |
Δ T_eut, end-T_eto | − 0.07 | Δ T_TS1 |
Δ t_eut, end-t_eto | − 1.00 | Δ t_TS1 |
Δ t_eut-t_eto | 3.94 | Δ t_TS2 |
dT/dt Eut, end – eto | − 749.22 | dT/dtTS1 |
dT/dt eut – eto | 2467.98 | dT/dtTS2 |
dT/dt liq – eto | 267.50 | dT/dtTS3 |
M (thermal modulus) | − 21.09 | MTS |
Geometry | Model tensile strength (MPa) | Measured tensile strength (MPa) | Deviation(%) |
|---|---|---|---|
YIItest block | 455.43 | 424.00 | 6.90 |
YIVtest block | 438.98 | 402.50 | 8.31 |
cylinder | 406.29 | 396.88 | 2.32 |
Source: Schüssler, J., Bührig-Polaczek, A.. Thermal Analysis of Ductile Iron: A New Way to Predict the Mechanical Properties. 2024-01-08. DOI: 10.1007/s40962-023-01222-3. Adapted from the open-access paper; original figure/table numbers retained. CC BY 4.0.Original paper · PDF · CC BY 4.0 ·